TM 11-6625-2478-12
(20) On SM-627/AYM-9, set ON-OFF switch to OFF.
t 0.10 inch in diameter (fig. 3-6).
(16) Remove camera cover assembly from access
(21) Loosen 10 captive fastener studs securing he
opening of Polaroid Camera CU-5 and slide cover
welded plate assembly cover and remove cover.
(22) Loosen captive fastener stud securing clamp
assembly along cable release to gain access to the
shutter speed and lens opening levers.
assembly C and remove IR RHA from the clamp
(17) Set camera shutter speed for a 1/15 second
assembly.
exposure time and set the lens opening to f/5.6 (para 3-
(23) Disconnect connector P2 of cable CX-12727 'U,
8b(3)).
removing the IR RHA.
(18) Slide the camera cover assembly along the
(24) Close clamp assembly C and secure with raptive
cable release and press camera cover assembly into
fastener stud.
(25) Rotate turntable assembly for maximum access
access opening of Polaroid Camera CU-5 to exclude
extraneous light.
to connector J1 (fig. 3-11).
(19) On SM427/AYM-9, set RHA TEST SELECT
(26) Disconnect connector P1 of cable CX-12727 /U
switch to PHOSPHOR.
from connector J1 on the internal sic of CY-
(20) Depress camera cable release.
7117/AYM-9.
(21) Develop exposed film (para 3-8b(4)). The
f Recorder, Code Matrix Block LA-4A Test Procedures.
(1) Connect connector P1 of Cable Assembly,
resulting print shall show a raster (fig. 3-7).
(22) On SM-627/AYM-9, set ON-OFF switch to
Special Purpose, Electrical CX-12726/U to the internal
OFF.
sic of connector J1 on the CY-7117/AYM-9. Connect
(23) Loosen 10 captive fastener studs securing
connector P2 t the connector on LA434A (fig. 3-11).
(2) Rotate turntable of KE-59A until spring-
the welded plate assembly cover and remove cover.
(24) Loosen captive fastener stud securing clamp
loaded locator pin locks into position B. (3)
Place
assembly B and remove LA434A from the clamp
LA434A on clamp assembly B and rotate the LA-434A
assembly.
until captive fastener on the body of LA-434A is in the
(25) Disconnect connector P2 of cable CX-
down position and in the space provided on clamp
assembly B.
12726/U, removing the LA434A.
(4) Position LA434A such that the front face is in line
(26) Close clamp assembly B and secure with
(5)
and parallel with the lens of the camera.
captive fastener stud.
(27) Rotate turntable assembly for maximum
Secure clamp assembly B by means of cap- tive
fastener stud.
access to connector J1 (fig. 3-11).
(6) Mount welded plate assembly cover on top of the
(28) Disconnect connector P1 of cable CX-
welded plate and secure with 10 captive fastener studs.
12726/U from connector J1 on the internal sic of
(7) On SM-627/AYM-9, set RHA TEST SELECT
CY-7117/AYM-9.
3-9. Stopping Procedure
switch to KA76.
(8) On SM4-627/AYM-9, set ON-OFF switch to
To stop operation of Test Set, Control Monitor-
ON.
Recording Head AN/AYM-9, proceed as follows:
(9) Remove camera cover assembly from access
a. Set ON-OFF switch to OFF (fig. 3-1).
b. Disconnect P2 of Cable Assembly, Power, Elec-
opening of Polaroid Camera CU-5 and slide cover
assembly along cable release to gain access to the
trical, CX-12723/AYM-9 from 115 volts, 400 Hz power
shutter speed and lens opening levers.
source (fig. 3-3). Disconnect P1 of Cable Assembly,
(10) Set camera shutter speed to T and set lens
Power, Electrical, CX-12723/AYM-9 from connector J4
opening to f/5.6 (para 3-8b(3)).
on Simulator, Monitor Input SM-627/AYM-9.
(11) Slide camera cover assembly along cable
c. Disconnect P1 of Cable Assembly, Special Pur-
release and press camera cover assembly into access
pose, Electrical CX-12725/U from connector J3 on
opening of Polaroid Camera CU-5 to exclude ex-
Simulator, Monitor Input SM-627/AYM-9. Disconnect P2
traneous light.
of Cable Assembly, Special Purpose, Electrical CX-
(12) Depress camera cable release.
12725/U from connector J1 on Case, Test
(13) On SM-627/AYM-5, depress SINGLE PULSE
Set CY-7117/AYM-9.
d. To secure Test Set, Control Monitor-Recording
pushbutton.  The SINGLE PULSE INDICATOR lamp
Head AN/AYM-9 after use, proceed as follows:
shall flash.
(1) Disconnect all cable assemblies from Test
(14) Depress camera cable release.
(15) Develop exposed film (para -8(4)). The
resulting print shall show a circle of small dots 0.35
3-13