(5) On SM-627/AYM-9, set RHA TEST SELECT
/U from connector J1 on the internal sic of CY-
switch to KA60, IR/SLAR, CDM.
7117/AYM-9.
(6) On SM-627/AYM-9, set ON-OFF switch to ON.
e. IR RHA Test Procedure.
(7) Remove camera cover assembly from access
opening of Polaroid Camera CU-5 and slide cover
(1) Connect connector P1 of Cable Assembly,
assembly along cable release to gain access to shutter
Special Purpose, Electrical CX-12727/U to the internal
speed lens opening levers.
sic of connector J1 on the CY-7117/AYM-9. Con nect
(8) Set camera shutter speed to T and set lens
connector P2 to connector on the IR RHA (fig. 3-11).
opening to f/8 (para 3-8 b(3)).
(2) Rotate turntable of KE-59A until spring- loaded
(9) Slide camera cover assembly along cable release
locator pin locks into position C.
and press camera cover assembly into ac- cess opening
(3) Mount IR RHA on clamp assembly C up to stop
of Polaroid Camera CU-5 to exclude extraneous light.
and secure clamp assembly by means of captive
(10) Depress camera cable release.
fastener stud.
(11) On S-627/AYM-9, depress SINGLE PULSE
(4) Mount welded plate assembly cover on top of the
pushbutton. The SINGLE PULSE INDICATOR
welded plate and secure with 10 captive fastener studs.
lamp shall flash.
(5) On SM-627/AYM-9, set the RHA TEST SE-
(12) Depress camera cable release.
LECT switch to KA60, IR/SLAR, CDM.
(13) Develop exposed film (para 3-8 b(4)).  The
(6) On SM-627/AYM-9, set ON-OFF switch to ON.
resulting print shall show a circle of small dots 0.6 0 .1
(7) Remove camera cover assembly from access
inch in diameter (fig. 3-5).
opening of Polaroid Camera CU-5 and slide cover
(14) Remove camera cover assembly from access
assembly along the cable release to gain access to
opening of Polaroid Camera CU-5 and slide cover
shutter speed and lens opening levers. (8) Set camera
assembly along cable release to gain access to shutter
shutter speed to T and set lens
opening to f/8 (para 3-8b(3)).
speed and lens opening levers.
(15) Set camera shutter speed for a 1/15 second
(9) Slide camera cover assembly along cable release
exposure time and set lens opening to f/5.6 (para 3- b
and press camera cover assembly into access opening
(3)).
of the Polaroid Camera CU-5 to exclude extraneous
(16) Slide camera cover assembly along cable
light.
release and press camera cover assembly into access
(10) Depress camera cable release.
opening of Polaroid Camera CU-5 to exclude extraneous
(11) On SM-627/AYM-9, depress SINGLE PULSE
light.
pushbutton. The PULSE INDICATOR lamp shall
(17) On SM-627/AYM-9, set RHA TEST SELECT
flash.
switch to PHOSPHOR.
(12) Depress camera cable release.
(13) Develop exposed film (para 3-8(4)). The
(18) Depress camera cable release.
(19) Develop exposed film (para 3-8 b (4)).  The
resulting print shall show a circle of small dots 0.6
resultant print shall show a raster (fig. 3-7).
0.1 inching diameter (fig. 3-5).
(20) On SM-627/AYM-9, set ON-OFF switch to OFF.
(14) Remove camera cover assembly from access
(21) Loosen 10 captive fastener studs securing the
opening of the Polaroid Camera CU-5 and slide cover
welded plate assembly cover and remove cover.
assembly along the cable release to gain access to the
(22) Loosen captive fastener stud securing clamp
shutter speed and lens opening levers. (15) Set camera
assembly C and remove SLAR RHA from the clamp
shutter speed for a 1/15 second exposure time and set
lens opening to f/5.6 (para 3-8(3)).
assembly.
(23) Disconnect connector P2 rod cable CX-
(16) Slide camera cover assembly along cable re-
12727/U, removing the SAR RHA.
lease and press camera cover assembly into access
NOTE
opening of the Polaroid Camera CU-5 to exclude
If IR RHA test is to be performed, omit
extraneous light.
steps (24) through (26).
(17) On SM-627/AYM-9, set RHA TEST SELECT
(24) Close clamp assembly C and secure with
switch to PHOSPHOR.
captive fastener stud.
(18) Depress camera cable release.
(25) Rotate turntable assembly for maximum
(19) Develop exposed film (para 3-8b(4). The re-
access to connector J1 (fig. 3-11).
sulting print shall show a raster (fig. 3-7).
(26) Disconnect connector P1 of cable CX-12727
3-12