TM1-6625-736-13&P
(d)
Press QUIT. Next select SAVE and EXIT. Then press DO.
(1)
Select MAIN MENU. Press DO.
(2)
Press F2 for DISPLAY.
(3)
Select One Test State. Press DO.
(4)
Select TRKTST. Press DO.
(5)
Select CHANNEL 1 TRACK. Press DO.
(6)
Press the right arrow once to target the green blade by setting the reference block from MEAN to
GRN. Press F3 for TABLE.
NOTE
All limits described in table 2-1 are referenced to the GRN blade. The values in parentheses
are the allowable limits in millimeters. Ensure CADU track DISPLAY is in the same scale. If
CADU track DISPLAY scale is in inches, multiply displayed track value by 25.4 or change the
scale with the MANAGER menu (refer to TM1-6625-724-13&P).
(e)
Examine the values given in the display and compare to table 2-1. If values are outside the tolerance
given, open UTD, inspect and replace the Printed Wire Assembly (PWA) in accordance with TM1-6625-
724-13&P.
(f)
Exit the TABLE screen by pressing QUIT three times.
(g)
Select DAY on the DAU Tracker Mode switch.
(h)
Repeat steps (c)(4)-(f).
Table 2-1. UTD Expected Output
Blade
Track
Lag
GRN
(0 ± 2 mm)
(0 ± 2 mm)
YEL
(2 ± 2 mm)
(-0.4 2 mm)
RED
(5 ± 2 mm)
(-0.7 2 mm)
BLU
(8 2 mm)
(-1.0 2 mm)
2-15/(2-16 Blank)
|