Page Title: (3) PROCEDURE TO VERIFY CALIBRATION OF THE DAU
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 1-6625-736-13&P (a) Ensure  external  power  and  both  the  DAU  and  CADU  power  switches  are  OFF.    Connect  the  DAU  to  an external bench power source of 28 Vdc.  :  (+28 VDC to pin B and -to pin A). (b) Establish a connection from the DAU jack labeled TRACKER 1 to the UTD/EPT jack on the Electronic Test Set using the UTD Cable, part number 29325701. (c) Connect  the  MULTI-CH  connection  on  the  DAU  to  the  MULTI-CH  connection  on  the  Electronic  Test  Set using cable part number 29283200. (d) Connect TACHO1 on the DAU to the MAG SEN connection on the Electronic Test Set using the Magnetic RPM Sensor Cable, part number 29105403. (e) For Test States 1:  4_1,, 1:  16_1 and 1:  64_1, connect ACC1 on the DAU to the connector ACC1 on the Electronic Test Set using the 25-ft 54 mv/g Accelerometer Cable, part number 29105605. (f) For Test States 1:  4_1, 1:  16_1 and 1:  64_1, connect ACC2 on the DAU to the connector ACC2 on the Electronic Test Set using the 50-ft 54 rv/g Accelerometer Cable, part number 29105600. (g) Connect the CADU to the DAU using cable part number 29325601.  This connection is made from the front panel of the DAU to the back panel of the CADU. (h) Position TRACKER MODE selector switch on the DAU to DAY. (i) If  a  printer  is  desired  refer  to  TM  1-6625-724-1  3&P  for  directions  on  how  to  connect  the  printer  to  the CADU. (j) Turn on external power source. (3) PROCEDURE TO VERIFY CALIBRATION OF THE DAU NOTE Failure to position the switches in the following order will result in erroneous calibration readings. (a) Set the switches on the Electronic Test Set to the following positions: (1) 54 mV/g 100 mV/g switches to 54 mV/g. (2) Active/Passive switch to PASSIVE (3) TACH 2 Mono pulse/Bi pulse switch to Bl PULSE. (4) TACH 1 Single/Double switch to SINGLE. (5) ACC Signal Select switch to 1:  4. (b) Turn the DAU power switch to ON. (c) Turn the CADU power switch to ON. 2-8  Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business