Click here to make tpub.com your Home Page

Page Title: NO. 1 SCALING AMPL Simulator.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 1-6625-735-14
c.
Connect multimeter to -15 VDC test point
and SIG GND. Multimeter shall indicate -15 6 0.15
5.26.3.2. Adjustments. Adjustments can not be
made.
vdc.
Adjustments. Adjustments can not be
CLTV STICK POSN Simulator.
made.
5.26.4.1. Performance Check.
5.26.2. NO. 1 SCALING AMPL Simulator.
a.
Connect multimeter to CLTV STICK
POSN NO. 1 SIM and NO. 1 SIG GND.
Performance Check.
b.
Place CLTV STICK POSN mode selector
a.
Connect multimeter leads to SCALING
control to SIM STAB 1 & 2.
AMP SIM NO. 1 and NO. 1 SIG GND.
c.
Rotate CLTV STICK POSN DN/UP con-
b.
Place SCALING AMP NO. 1 mode select
trol fully CCW. Multimeter shall indicate 7.16 6 0.74
control to SIM.
vdc.
c.
Place STAB 1 & 2/SINGLE control to
d.
Rotate CLTV STICK POSN DN/UP con-
SINGLE.
trol fully CW. Multimeter shall indicate -7.16 6 0.74
d.
vdc.
Rotate SCALING AMPL DN/UP NO. 1
control fully counterclockwise (CCW). Multimeter
shall indicte 10.27 6 0.4 vdc.
Adjustments. Adjustments can not be
made.
e.
Rotate SCALING AMPL DN/UP NO. 1
control fully clockwise (CW). Multimeter shall indicte
5.26.5. AS SENSOR Simulator.
-10.27 6 0.4 vdc.
5.26.5.1. Performance Check.
Adjustments. Adjustments can not be
made.
a.
Connect multimeter to AS SENSOR SIM
NO. 1 and NO. 1 SIG GND.
NO. 2 SCALING AMPL Simulator.
b.
Place AS SENSOR mode selector control
Performance Check.
to SIM STAB 1 & 2.
c.
a.
Rotate AS SENSOR DECR/INCR control
Connect multimeter to SCALING AMP
fully CCW. Multimeter shall indicate 0 6 0.15 vdc.
SIM NO. 2 and SIG GND.
d.
b.
Rotate AS SENSOR DECR/INCR control
Place SCALING AMP NO. 2 mode select
fully CW. Multimeter shall indicate 12.2 6 1.25 vdc.
control to SIM
e.
c.
Connect multimeter to AS SENSOR SIM
Make sure SCALING AMPL STAB 1 &
NO. 2 and NO. 2 SIG GND. Multimeter shall indicate
2/SINGLE control is in SINGLE.
12.2 6 1.25 vdc.
d.
Rotate SCALING AMPL DN/UP NO. 2
control fully CCW. Multimeter shall indicte 10.27 6
f.
Place AS SENSOR mode selector control
to SIM STAB 1. Multimeter shall indicate 2.3 6 0.1
0.4 vdc.
vdc.
e.
Rotate SCALING AMPL DN/UP NO. 2
control fully CW. Multimeter shall indicte -10.27 6
5.26.5.2. Adjustments. Adjustments can not be
made.
0.4 vdc.

Privacy Statement - Press Release - Copyright Information. - Contact Us