TM 1-6625-735-14
TABLE NO. 3-37.
Test Set Indicator Lamps Do Not Go On When 28 Vdc Power Is Jumpered To Test
Point/Connector Contact Listed. (Cont)
TEST OR INSPECTION
CORRECTIVE ACTION
2. Connect jumper between POWER 28 VDC STAB 1 and connector contact and/or
test point as listed. INDICATORS, corresponding to connector contact and/or test
point, shall light.
Step 1. If INDICATORS corresponding to connector contact and/or test point do not
go on, replace malfunctioning lamp and retest.
Step 2. If trouble remains, replace component board assembly A3.
CONNECTOR CONTACT (TEST POINT INDICATORS)
J1-C (NO. 1 INTLK 28 OS)
J2-C (NO. 2 INTLK 28 OS)
J1-A (NO. 1 INTLK 28)
J2-A (NO. 2 INTLK 28)
J1-BB (NO. 1 AUTO ENGA)
J2-BB (NO. 2 AUTO ENGA)
J1-GG (NO. 1 AUTO ENGA OS)
J2-GG (NO. 2 AUTO ENGA OS)
J1-V (NO. 1 DRVR SUPPLY)
J2-V (NO. 2 DRVR SUPPLY)
J1-B (NO. 1 DRVR SUPPLY OS)
J2-B (NO. 2 DRVR SUPPLY OS)
J1-s (NO. 1 UP LIMIT)
J2-s (NO. 2 UP LIMIT)
J1-E (NO. 1 STAB UP)
J2-E (NO. 2 STAB UP)
J1-D (NO. 1 STAB DN)
J2-D (NO. 2 STAB DN)
J1-t (NO. 1 DN LIMIT)
J2-t (NO. 2 DN LIMIT)
J3-E (SAS ENGAGE 2)
J3-G (SAS ENGAGE 1)
3-33
|