Turned Clockwise To A Multimeter No. 1 Indication Between 12.0 6 0.5 Vdc.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Connect orange banana plug of locally-made cable to AS SENSOR SIM NO. 1 test
jack. Go to 2.
2. Connect multimeter (No. 1) between AS SENSOR SIM NO. 1 and SIG GND test
jacks. Go to 3.
3. Connect multimeter (No. 2) between SAS SIG REF ROLL/YAW and SIG GND test
jack. Go to 4.
4. Place AS SENSOR control to SIM STAB 1&2. Go to 5.
5. Set AS SENSOR control to a multimeter (No. 1) indication 12.0 6 0.5 vdc. Multi-
meter (No. 2) shall indicate 12.0 6 0.7 vdc.
Step 1. If multimeter indication is not correct, replace circuit board assembly A2.
Step 2. If multimeter indication is correct, go to 6.
6. Set AS SENSOR control counterclockwise until multimeter (No. 1) indicates 5.0 6
0.5 vdc. Multimeter (No. 2) shall indicate 5.1 6 0.6 vdc.
Step 1. If multimeter indication is not correct, replace circuit board assembly A2.
Step 2. If multimeter indication is correct, go to 7.
7. Place AS SENSOR control to OFF. Go to 8.
8. Place YAW RATE control to NORM. Go to 9.
9. Remove orange banana plug from AS SENSOR SIM NO. 1 test jack. Go to 10.
10. Remove digital multimeters from test set.
TABLE NO. 3-37.
Test Set Indicator Lamps Do Not Go On When 28 Vdc Power Is Jumpered To Test
Point/Connector Contact Listed.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Pull out POWER 28 VDC circuit breakers CB1 and CB2, and TEST SET circuit
breaker CB4. Go to 2.