Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
NO. 1 and NO. 2 BFR
Provide monitoring and testing capabilities of actuator position buffer.
ACTR POSN Test Points
NO. 1 and NO. 2 ACTR
Provide monitoring and testing capabilities of opposite actuator position buffer.
POSN (OS) Test Points
Signal from NO. 1 BFR ACTR POSN test point is supplied to NO. 2 ACTR
POSN (OS) test point. Signal from NO. 2 BFR ACTR POSN test point is sup-
plied to NO. 1 ACTR POSN (OS) test point.
NO. 1 and NO. 2 I
Provide monitoring capability for No. 1 and No. 2 stabilator amplifier current
LIMIT SWITCHED Test
sense fault monitor circuit output signals when FAULT MONITOR I LIMIT 1
Points
and 2 controls are at NORM. When FAULT MONITOR I LIMIT 1 and 2 con-
trols are at INHIBIT, NO. 1 and NO. 2 I LIMIT SWITCHED test points pro-
vide monitoring of grounds supplied by test set to No. 1 and No. 2 stabilator
amplifiers to disable current sense fault monitor circuits.
, provide monitoring capability for actuator window positive com-
MH-60K NO. 1 and NO.
MH-60K
parator testing.
2 COMPTR TST (+) Test
Points
MH-60K NO. 1 and NO.
, provide monitoring capability for 26 vac 2 supplied by No. 1
MH-60K
2 26VAC 2 Test Points
and No. 2 stabilator amplifiers which is used in each pitch rate gyro.
INDICATORS
Go on and off to indicate functional conditions of stabilator system operation.
NO. 1 indicators relate to No. 1 stabilator amplifier and NO. 2 indicators relate
to No. 2 stabilator amplifier.
HOT SLEW indicators go on to indicate manual slew switch on stabilator
NO. 1 and NO. 2 SLEW
control/auto flight control panel is being used and that stabilator system is in
UP, NO. 1 and NO. 2
manual mode. SLEW UP or SLEW DN indicators go on to indicate direction
SLEW DN, and HOT
of slewing command.
SLEW Indicators
NO. 1 and NO. 2 RESET
Go on to indicate reset switch on stabilator control/auto flight control panel is
Indicators
pressed.
Go on to indicate stabilator is operating in automatic mode. Power that turns
NO. 1 and NO. 2 AUTO
on NO. 1 AUTO ENGA indicator also turns on NO. 2 AUTO ENGA OS indi-
ENGA and NO. 1 and
cator. Power that turns on NO. 2 AUTO ENGA indicator also turns on NO. 1
NO. 2 AUTO ENGA OS
AUTO ENGA OS indicator.
Indicators
Go on to indicate No. 1 and No. 2 stabilator amplifier-driver amplifiers are
NO. 1 and NO. 2 DRVR
being supplied 28 vdc power. Power that turns on NO. 1 DRVR SPLY indica-
SPLY and NO. 1 and NO.
tor also turns on NO. 2 DRVR SPLY OS indicator. Power that turns on NO. 2
2 DRVR SPLY OS Indi-
DRVR SPLY indicator also turns on NO. 1 DRVR SPLY OS indicator.
cators
STAB UP indicators go on, indicating stabilator trailing edge is moving up.
NO. 1 and NO. 2 UP
UP LIMIT indicators go on indicating stabilator has reached maximum
LIMIT and NO. 1 and
up-limit. When stabilator up-limit is reached and UP LIMIT indicators go on,
NO. 2 STAB UP Indica-
STAB UP indicators go off.
tors
STAB DN indicators go on, indicating stabilator trailing edge is moving down.
NO. 1 and NO. 2 STAB
DN LIMIT indicators go on indicating stabilator has reached maximum down-
DN and NO. 1 and NO. 2
limit. When stabilator down-limit is reached and DN LIMIT indicators go on,
DN LIMIT Indicators
STAB DN indicators go off.
2-24