1.7.4.  SAS SYSTEM Section. The SAS SYS-
1.6.
EQUIPMENT CHARACTERISTICS AND
FEATURES.
TEM section of the test set has 15test points and three
monitor lamps to provide access to system signal
The test set provides the AVUM technician with the
points and to visually indicate system conditions. It
capability to monitor and simulate signals to and from
also provides airspeed simulation, yaw rate gyro
AFCS.
UH-60A
UH-60L
EH-60A
simulation, and a roll attitude simulation. The roll atti-
The computer test point panel monitors
UH-60Q
tude simulation is by means of a synchro transmitter
inputs and outputs from the SAS/FPS computer.
control.
The STABILATOR SYSTEM portion of the test set
allows monitoring of various input/output/operating
1.7.5.  LAMP TEST Switch. The LAMP TEST
voltages by means of lights and test points. It also
switch provides a voltage to all STABILATOR SYS-
provides sensor simulators to input signals to the sys-
TEM INDICATORS lamps and to the three SAS
tem under test. The SAS SYSTEM portion of the test
SYSTEM indicator lamps.
set provides lamps and test points to monitor input
and output signals, and sensor simulators to provide
1.7.6.  POWER Section. The POWER section
signal inputs.
provides lamp monitoring, test points, and circuit
breaker protection for input and output voltages.
LOCATION AND DESCRIPTION OF
MAJOR COMPONENTS.
EQUIPMENT DATA.
1.7.1. Carrying Cases. The test set is made up of
The following is a listing of the technical characteris-
two carrying cases. The cable case assembly contains
tics of the stabilization system test set equipment.
all the interconnecting cable assemblies. The test unit
case contains the computer test point panel in the
AC voltage
115 vac, 1, 400 Hz
upper hinged half of the case and the STABILATOR
DC voltage
27.5 to 28.5 vdc
SYSTEM and SAS SYSTEM test points, lamps, and
Outputs
Simulated
simulators in the lower hinged half of the case.
1.7.2. Computer Test Point Panel  UH60A
Dimensions -
The computer test
UH60L
EH60A
UH-60Q
Test unit
55.88 cm (22 in.) x 43.18
point panel is connected to the SAS/FPS computer by
(l x w x h)
cm (17 in.) x 35.56 cm (14
the three cable assemblies which connect to test set's
in.)
J4, J5, and J6. The test points correspond to related
Cable case
66.04 cm (26 in.) x 45.72
pins on the SAS/FPS computer connectors and are in
assembly
cm (18 in.) x 21.59 cm (8.5
parallel with them.
(l x w x h)
in.)
Volume -
1.7.3. STABILATOR SYSTEM Section. The
Test unit
0.09 cubic meter (3.0 cu ft)
STABILATOR SYSTEM section of the test set has
Cable case
0.069 cubic meter (2.3 cu
30 INDICATORS which represent system conditions.
assembly
ft)
There are 51 TEST POINTS on the test set which are
used to provide access to signal and voltage condi-
Weight -
tions within the system. The simulator sections con-
Test unit
21.9 kg (48.7 lbs)
tain variable controls, mode selector controls, and test
Cable case
19.8 kg (44 lbs)
points. These simulator sections can input, if selected,
assembly
simulated sensor and circuit operation. This portion of
the test set also provides manual slew, fault monitor-
ing and reset capabilities.