TM 55-6695-220-13&P
3-12.
CABLE ASSEMBLIES- INSPECT/REPAIR/REPLACE. (Contd)
3-12
2. REPAIR.
a. Cut out section of broken copper strands and solder prepared end of lead to alligator clip.
b. Cut out section of frayed insulation or broken strands on cable adapter wire and resolder.
c. If wire is too short replace with new wire.
Figure 3-6. Thermocouple Test Lead
3. REPLACE.
a. Install cable clamp on cable connector and secure with two screws, using medium screw driver (See Figure 3-7).
b. Slide insulated boots onto alligator clips (See Figure 3-6).
END OF TASK
Figure 3-7. Pyrometer Test Lead
3-21
|