TM 55-4920-430-13
VOLTAGE
DIGITAL
MEASUREMENT
CONTROL/SWITCH
STEP
NO.
NOMENCLATURE POSITION
TEST PROCEDURES
NORMAL RESULTS
(a) None
(51)
(a) RANGE switch (a) 20V
(a) None
S6
(b) 1.000
(b) None
(b) None
(b) TIME DELAY-
SEC switch S9
( c ) APPLY
(c) RESPONSE
(c) +4.237 to +4.611
(c) None
TEST STIM
Vdc
switch S7
(d) REMOVE
(d) None
(d) RESPONSE
(d) None
TEST STIM
switch S7
(a) None
(a) AC/DC VOLT- (a) 60, 0, A,
(a) None
(52)
METER CIRCUIT 0
SELECT switches
(b) -0.06 to +0.06Vdc
(b) TIME DELAY-
(b) Remove 1 meg-
(b) 00.062
SEC switch S9
ohm resistor.
Remove 1 uf
capacitor.
Connect jumper
between J3-PP and
J2-36
(c) RESPONSE
(c) APPLY
(c) +4.111 to +4.729
(c) None
TEST STIM
Vdc
switch S7
(d) RESPONSE
(d) REMOVE
(d) None
(d) None
TEST STIM
.
switch S7
(e) None
(e) RESPONSE
(e) None
(e) OFF
TEST MODE
switch S8
(f) None
(f) None
(f) XFEED
(f) 2
ROLL ATT
switch S54
(g) None
(g) Disconnect all
(g) AC/DC VOLT-
(g) 00, 0, B
test connections
METER CIRCUIT 0
SELECT switches
4-72
|