TM 55-4920-430-13
DIGITAL
VOLTAGE
STEP
CONTROL/SWITCH
POSITION
MEASUREMENT
NO.
NOMENCLATURE
NORMAL RESULTS
a.
(1) ROLL
( 1 ) None
(1) ATT SELECT
( 1 ) None
switch S35
( 2 ) ATT Synchro
( 2 ) None
( 2 ) None
(2) 0.0
( C o r r e s p o n d s to 0.0
of roll)
( a ) J3-V (line)
(a)
-0.05 to +0.05 Vac
to J3 -U
( b ) J3-T (line)
( b ) -9.69 to -10.71 Vac
to J3-V
( c ) J3-T (line)
( c ) -9.69 to -10.71 Vac
to J3-U
(3) ON
-0.05 to +0. 05Vac
( 3 ) RESPONSE
J3-V (line)
(a)
(a)
to J3-U
TEST MODE
switch S8
( b ) -0.05 to +0.05Vac
J3-T (line)
(b)
to J3-V
(c)
- 0 . 0 5 to +0.05Vac
(c)
J3-T (line)
to J3-U
(d)
( d ) -0.05 to +0.05Vac
J3-X (line)
to J3-W
(e)
- 9 . 6 9 to -10.71Vac
J3-Y (line)
(e)
to J3-X
(f)
(f)
J3-Y (line)
- 9 . 6 9 to -10.71Vac
to J3-W
b.
( 1 ) RESPONSE
(1) OFF
( 1 ) None
( 1 ) None
TEST MODE
switch S8
(2) 330.0
( 2 ) ATT Synchro
( 2 ) None
( 2 ) None
-5.6 to -6.2Vac
( a ) J3-V (line)
(a)
to J3-U
( b ) J3-T (line)
(b) -5.6 to -6.2Vac
to J3-V
4-36
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |