TM 55-4920-430-13
METER/lNDICATOR
CONTROL/SWITCH
STEP
NORMAL RESULTS
POSITION
NOMENCLATURE
NO.
112.2 to 117.7 VAC
ON,
AFCS POWER 115V/400 Hz
c.
then
OFF
DC
d.
METER
00-2
-0.6 to +0.6 VDC
SELF-TEST CIRCUIT SELECT
24 to 28.5 VDC
ON,
AFCS POWER +28 VDC
e.
then
OFF
20V
METER RANGE
f.
+14.9 to +15.l
00-3,
SELF-TEST CIRCUIT SELECT
then
00-4
-14.9 to -15.l VDC
then
00-5
4.9 to 5.l
AC
METER
g.
00-6
SELF-TEST CIRCUIT SELECT
4 to 6 VAC
AFCS POWER
ON,
then
OFF
h.
12 to 14
SELF-TEST CIRCUIT SELECT
00-7,
then
12 to 14 VAC
00-8
i.
METER RANGE
200 V
24 to 28 VAC
SELF-TEST CIRCUIT SELECT
00-9
METER RANGE
20 V
j.
METER
DC
+14.9 to +15.1 VDC
SELF-TEST CIRCUIT SELECT
10-0,
then
-14.9 to -15.1 VDC
10-1
0.06 to +0.06 VDC
ON
k.
RESPONSE TEST MODE
-0.06 to +0.06 VDC
10-0
1.
SELF-TEST CIRCUIT SELECT
m.
METER RANGE
200 V
METER
AC
-0.6 to +0.6 V A C
SELF-TEST CIRCUIT SELECT
10-2
OFF
RESPONSE TEST MODE
n.
METER RANGE
20V
12 to 14 VAC
SELF-TEST CIRCUIT SELECT
10-3
then
10-4
12 to 14 VAC
RESPONSE TEST MODE
ON
o.
0 to 0.1 VAC
SELF-TEST CIRCUIT SELECT
30,3
then
10-4
0 to 0.1 VAC
RESPONSE TEST MODE
OFF
p.
SELF-TEST CIRCUIT SELECT
20-0
All DISCRETE MONITORS lights
ON.
All CONTROL PANEL SIMULA-
TION lights ON.
RESPONSE TEST HOLD light ON.
CONTINUITY TEST HOLD It ON.
Change 1
4-30
|