Click here to make tpub.com your Home Page

Page Title: Ac/Dc Voltmeter Tests (CRC)-continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM
55-4920-430-13
d. Disconnect the ac power supply and the digital multimeter from the EXTERNAL METER jacks.
e. Set the METER switch to DC.
f. Connect the positive terminal of the variable dc power supply and positive test lead of the digital
multimeter to EXT METER HI jack J8. Connect the negative terminal of the dc power supply and the
negative test lead of the digital multimeter to EXT METER LO jack J9. Set the digital multi meter to
read dc voltage. Adjust the dc power supply to the input levels listed below. For each dc input level, the
AC/DC VOLTMETER reading shall be as listed below. (See fig. 4-7.)
AC/DC
DC
METER
VOLTMETER READING (DC)
INPUT LEVEL
RANGE SWITCH
.
200 MV
50.0 mV
49.0 to 51.0 mV
100.0 mV
98.4 to 101.6 mV
150.0 mV
147.8 to 152.2 mV
190.0 mV
187.3 to 192.7 mV
220.0 mV
flashing
2V
0.500
V
0.495 to 0.505 V
1.000
V
0.995 to 1.005 V
1.500
V
1.494 to 1.506 V
1.900
V
1.894 to 1.906 V
2.200
V
flashing
20 V
5 .00 V
4.94 to 5.06 V
10.00 V
9.93 to 10.07 V
15.00 V
14.91 to 15.09 V
19.00 V
18.90 to 19.10 V
22.00 V
flashing
200 V
5.0 V
+4.6 to +5.4 V
15.0 V
+14.5 to +15.5 V
30.0 V
+29.4 to +30.6 V
4-23