TM 55-4920-430-13
Table 2-3. Self Test -- Continued
METER/lNDICATOR
SWITCH OR CONTROL
POSITION
NORMAL RESULT
+24 to +28.5 VDC
ON
AFCS POWER +28VDC
then
OFF
20V
METER RANGE
+14.9 to+15.1 VDC
00-3
SELF TEST CIRCUIT SELECT
then
14.9 to-15.l VDC
00-4
then
+4.9 to +5.1 VDC
00-5
AC
METER
0.0 to 0.2 VAC
00-6
SELF TEST CIRCUIT SELECT
4 to 6 VAC
ON
AFCS POWER l15V/400 HZ
then
OFF
12 to 14 VAC
00-7
SELF TEST CIRCUIT SELECT
then
12 to 14 VAC
00-8
200V
METER RANGE
24 to 28 VAC
00-9
SELF TEST CIRCUIT SELECT
20V
METER RANGE
METER
DC
+14.9 to+15.l VDC
10-0
SELF TEST CIRCUIT SELECT
then
-14.9 to-15.1 VDC
10-1
-0.06 to +0.06 VDC
RESPONSE TEST MODE
ON
0.06 to +0.06 VDC
10-0
SELF TEST CIRCUIT SELECT
METER RANGE
200V
METER
AC
-0.6 to 0.6 VAC
SELF TEST CIRCUIT SELECT
10-2
RESPONSE TEST MODE
OFF
METER RANGE
20V
12 to 14 VAC
SELF TEST CIRCUIT SELECT
10-3
then
12 to 14 VAC
10-4
RESPONSE TEST MODE
ON
10-3
0.0 to 0.1 VAC
SELF TEST CIRCUIT SELECT
then
0.0 to 0.1 VAC
10-4
RESPONSE TEST MODE
OFF
Change 1
2-24
|