TM 55-4920-412-13&P p. Analog  Processor  No.  1  Assembly  (A9).    Shift Reg  Drive  and  reset  from  (A6)  and  ANA  PROC  No.  2 Circuits. (1) Connect    test    equipment    as    shown    in Figure 4-1, unit tester connected.  Set Power to OFF and remove   Analog   Processor   Board   on   extender   board. Insert extender board into unit tester. (2) Place  INTER  CAL  SELECT  switch  to  21. Connect  digital  voltmeter  leads  between  test  loops  4  (+) and  118  (-).    Set  Power  to  ON.    Digital  voltmeter  will indicate    between    4.5    and    5.5    vdc.        If    not,    see troubleshooting table 4-34. (3) Set   Power   to   OFF.      Disconnect   digital voltmeter leads from unit tester. (4) Set Power to OFF and connect oscilloscope  between  test  loops  54  (HI)  and  118  (LO). Set   power   to   ON.      Oscilloscope   will   display   positive- going  square  wave  pulses  4.5  to  5.0  V  p-p.    If  not,  see troubleshooting table 4-34. (5) Set power to OFF.  Disconnect from test loop 54. (6) Connect  oscilloscope  to  test  loop  38  and set power to ON. Oscilloscope will display approximately 10 micro seconds reset pulse momentarily   as   indicated   when   Inter   Face   Monitor   is resetting.  If not, see troubleshooting table 4-34. (7) Set power to OFF and disconnect oscilloscope from test loop 38 and reconnect oscilloscope to test loop 42. (8) Set    power    to    ON.        Oscilloscope    will display positive going pulse, 4.5 to 5.5 V p-p.  If not, see troubleshooting table 4-34. (9) Set power OFF and disconnect oscilloscope from test loop 42 and reconnect to 22. (10) Set    power    to    ON.        Oscilloscope    will display  positive  going  pulses  4.5  to  5.5  V  p-p.    Observe oscilloscope  DC  level  shifting  from  ground  to  +5  v  with Interface  Monitor  count  between  950  and  1000,  shifting back from ground when Interface Monitor resets to zero. If not, see troubleshooting table 4-34. Table 4-34.  Troubleshooting Analog Processor Board No. 1 (A9), Shift Reg Drive and Reset, Ana Proc No. 2 Trouble Probable Cause Remedy 5 vdc low or missing Logic Power Supply A3.  INPUT 8V Replace defective components or missing to Regulator Board (A4) or Regulator Board (A4).  See figs. 4-13, Output 5V missing.  Analog Proces- 4-14, 4-21, FO-6, FO-7, FO-8, FO-13. sor #2 (A10). Shift Reg Drive has incorrect Input Inter Cal Select switch, interwiring Replace defective components or re- from Board (A6) Board.  OSC Board (A6).  Analog place board (A6).  See figs. 4-14, 4-16, Processor No. 2 (A10). 4-21, FO-6, FO-8, FO-10, FO-13. Shift Reg Reset input missing from Inter Cal Select switch, interwiring Replace defective components or re- Board (A6) Board.  OSC Board (A6).  Analog place board (A6).  See figs. 4-16, 4-21, Processor No. 2 (A10) FO-6, FO-10, FO-13. ANA PROC No 2 Output incorrect Analog Processor No. 1 (A9).  OSC Replace defective components or re- Board (A6). place boards (A6), (A9).  See figs. 4-16, 4-22, FO-10, FO-14. 4-64

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business