TM 55-4920-412-13&P (23) Digital    multimeter    will    indicate    between +4.5  and  +5.5  vdc.    If  not,  see  Troubleshooting  Table 4-32. (24) Set  P/S  control  to  REMOTE.    Disconnect digital multimeter LEAD from J9 pin 19 and reconnect to ILS test point Digital multimeter will indicate between 4.5 and 5.5 vdc.  If not, see Troubleshooting Table 4-32. (25) Set   Power   Switch   to   OFF.      Disconnect digital multimeter. (26) Connect    oscilloscope    to    test    loop    37 (TIEST FREQ).  Set Power Switch to ON. (27) Oscilloscope    will    display    positive-going test   frequency   pulses   4.5   to   5.5   Vp-p.      If   not,   see troubleshooting table 4-32. (28) Set Power Switch  to  OFF  and  disconnect oscilloscope  lead  from  test  loop  37  and  connect  digital voltmeter leads to test loop 10.  Set Power Switch to ON. Digital  multimeter  will  indicate  between  -4.5  to  -5.5  vdc. If not, see troubleshooting table 4-32. (29) Set Power  Switch  to  OFF  and  disconnect digital multimeter from test loop 10. (30) Connect  oscilloscope  to  test  loop  7.    Set power  switch  to  ON.    Oscilloscope  will  display  positive- going reset pulse approximately 1.6 seconds in direction when    interface    monitor    is    resetting.        If    not,    see troubleshooting table 4-32. (31) Set  Power  Switch  to  OFF  and  disconnect oscilloscope  from  test  loop  7  and  reconnect  to  test  loop 13. (32) Set   Power   Switch   to   ON   and   observe approximately 10 micro seconds reset pulse momentarily  when  interface  monitor  is  resetting.    If  not, see troubleshooting table 4-32. o. Processors   Selection   -   Analog   AB/Digital   A3, Wiring Verification, Fail Warn Lamp, Test Freq- ANAIDIG.  B C D Counter Board (AS) Circuits. (1) Set Power Switch to OFF. (2) Remove  B  C  D  Counter  Board  (A5)  and reconnect extender board. (3) Connect jumper between loops 44 (ground) and 28 on extender board. (4) Set Power Switch to ON.  Fail Warn Light. If not, see Troubleshooting Table 4-33. (5) Set Power Switch to OFF. (6) Remove jumper from extender board. (7) Connect   jumper   between   test   loops   39 and 1 (5v). (8) Set  Power  Switch  to  ON.    Test  Freq  Dig Light will light.  If not, see troubleshooting table 4-33. (9) Set Power Switch to OFF. (10) Remove jumper from extender board. (11) Connect   jumper   between   test   loops   43 and 1 (Sv). (12) Set  Power  switch  to  ON.    Test  Freq  ANA Light will light.  If not, see troubleshooting table 4-33. (13) Set Power switch to OFF. (14) Repeat  technique  (9)  through  (13)  above for  each  test  loop  connections  33  and  1  (Select  B  DIG PROC);  35  and  (Select  A  DIG  PROC);  37  and  1  (Select A ANA PROC); 41 and 1 (Select B ANA PROC).  Lights will    light    for    each    circuit    connection.        If    not,    see troubleshooting table 4-33. (15) Set power switch to OFF. (16) Disconnect  jumper  lead  from  test  loop  41 and 1. (17) Connect oscilloscope and Frequency Counter between test loops 15 (HI) and 44 (LO). (18) Set   Power   Switch   to   ON.      Oscilloscope shall display positive going square wave pulses between 4.5 and 5.5 Vp-p.  If not, see troubleshooting table 4-33. (19) Set Power Switch to OFF. (20) Repeat     techniques     (15),(17)     and     (19) above,  connecting  oscilloscope  to  each  test  loop  output as   shown   in   fig   4-18   for   units,   tens,   hundreds   and thousands.      Check   in   order   shown   for   positive   going square   wave   pulses   between   4.5   and   5.5   Vp-p   with successively  longer  periods.    If  not,  see  troubleshooting table 4-33. (21) Oscilloscope    shall    display    each    output momentarily going to +5 vdc and returning to zero. (22) Set Power Switch to OFF. (23) Disconnect oscilloscope from test loop 3. (24) Connect  to  test  loop  22  and  set  power  to ON. (25) Oscilloscope   should   display   reset   pulse input.      Interface   Monitor   will   reset   to   zero   and   begin counting. 4-60  Change 2

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business