Page Title: Table 4-25. Troubleshooting Rotor Overspeed,
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 55-4920-412-13&P f. Rotor  Overspeed  127%,  137%,  142%,  sensing A  or  B,  Rotor  SPEED,  ENG  1  OUT,  ENG  2  OUT,  OIL  1 PRESS,  OIL  2  PRESS,  OIL  1  TEMP  and  OIL  2  TEMP, INT LIGHT, Lamp circuits. (1) Press  LAMP  TEST  switch  on  simulator  to light Lamps before troubleshooting circuits. (2) Refer  to  schematic  FO-6  to  troubleshoot applicable circuits. (3) Troubleshooting Table 4-25 identifies probable causes of trouble. Table 4-25.  Troubleshooting Rotor Overspeed, 127%o 137%, 142%, Sensing, Rotor Speed, ENG 1 OUT, ENG 2 OUT, OIL 1 PRESS, OIL 2 PRESS, OIL 1 TEMP, OIL 2 TEMP, INT LIGHT, LAMP CIRCUITS. NOTE Voltage input is from CDU or SDC when testing. Trouble Probable Cause Remedy Rotor 127% overspeed lamp will not Redundant Warn O/P switch (S7), Replace defective components, FO-6 light Lamp Test Board Rotor 137% overspeed lamp will not Redundant Warn O/P switch (S7), Replace defective components, FO-6 light Lamp Test Board Rotor 142% overspeed lamp will not Redundant Warn O/P switch (S7) Replace defective components, FO-6 light Lamp Test Board Sensing A or B lamps will not light Lamp Test Board, J3 or J2 con- Replace defective components, FO-6 nector Rotor speed lamp will not light S7, Interconnecting cable, J3 or J2 Replace defective components, FO-6 connectors, Lamp Test Board ENG 1 OUT or ENG 2 OUT lamps Lamp Test Board, J3 or J2 con- Replace defective components, FO-6 will not light nector OIL 1 PRESS or OIL 2 PRESS Lamp Test Board, J2 or J3 con- Replace defective components.  FO-6 lamps will not light nector High OIL Temp 1 or 2 lamps will Lamp Test Board, J2 or J3 con- Replace defective components, FO-6 not light nector INT light lamps will not light Lamp Test Board, J8 or J9 con- Replace defective components, FO-6 nector 4-50

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business