TM 55-4920-412-13&P Table 3-1.  Operator's Controls (Cont) Control, indicator or connector Function SENSOR SIMULATOR (Cont) GAS GEN SPEED NO. 2 NOR CAL switch Permits  selection  of  mode  of  operation  for  equipment  testing  of  Ng  #2 indicator. HI LO switch Permits  selection  of  high  and  low  Calibration  tests  for  Ng  #2  indicator when NOR CAL switch is placed to CAL. Variable control Used  to  check  range  of  operation  of  Ng  #2  indicator  when  NOR  CAL switch is placed to NOR. HIGH OIL TEMP NO. 1 Used to indicate simulated conditions exist on appropriate HIGH OIL TEMP NO. 2 parameter tests. ENGINE OUT NO. 1 ENGINE OUT NO. 2 ENGINE % RPM NO. 1 NOR CAL switch Used  to  select  mode  of  operation:  normal  or  Calibration  of  %  RPM  #1 indicator. HI LO switch Used  to   select   high   and   low   speed   Calibration   points   of   %   RPM   #1 indicator when NOR CAL switch is placed to CAL. Variable control Used when NOR CAL switch is placed to NOR, to check operation   of   % RPM Engine #1 indicator over its range. ENGINE % RPM NO. 2 NOR CAL switch Selects    mode    of    operation    for    %    RPM    #2    indicator    -    normal    or Calibration. HI LO switch Used  to  select  high  and  low  Calibration  points  for  %  RPM  #2  indicator when NOR CAL switch is placed to CAL. Variable control Used when NOR CAL switch is placed  to  NOR,  to  check  operation  of  % RPM #2 indicator over its range. TORQUE NO. 1 NOR CAL switch Used  to  select  mode  of  testing  -  normal  or  Calibration  of  %  TRQ  #1 indicator. HI LO switch Permits   selection   of   high   and   low   Calibration   of   %   TRQ   #1   indicator checks when NOR CAL switch is placed to CAL. Variable control Permits testing of range of operation of % TRQ #1 indicator system when NOR CAL switch is at NOR. TORQUE % NO. 2 NOR CAL switch Used  to  select  mode  of  testing  -  normal  or  calibration  of   %   TRQ   #2 indicator. HI LO switch Permits   selection   of   high   and   low   calibration   checks   of   %   TRQ   #2 indicator when NOR CAL switch is placed to CAL. Variable control Permits testing of range of operation of % TRQ #2 indicator system when NOR CAL switch is at NOR. 3-6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business