Page Title: Table 3-1. Operator's Controls (Cont)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 55-4920-412-13&P Table 3-1.  Operator's Controls (Cont) Control, indicator or connector Function Variable control Used  to  check  complete  range  of  operation  of  #2  engine  oil  pressure when NOR CAL switch Is placed to NOR. LOW OIL PRESS NO. 1 Used to indicate simulated conditions exist on appropriate LOW OIL PRESS NO. 2 parameter tests. XMSN OIL PRESS NOR CAL switch Used to select testing mode: either fixed calibration operation or variable (controllable) operation. HI LO switch Used  to  select   high   and   low   fixed   calibration   points   for   transmission pressure indicator when NOR CAL switch is placed to CAL Variable control Used   to   check   complete   range   of   operation   of   transmission   pressure indicator when NOR CAL switch is placed to NOR. XMSN OIL TEMP NOR CAL switch Used  to  select  testing  mode  of  transmission  oil  temperature  indicator  in either normal or calibrating functions. HI LO switch Used   to   select   high   and   low   calibration   points   for   transmission   oil temperature indicator, when NOR CAL switch is placed to CAL Variable control Used  to  check  full  range  of  transmission  oil  temperature  indicator  when NOR CAL switch is placed to NOR. TURBINE GAS TEMP NO. 1 NOR CAL switch Permits  selection  of  mode  of  operation  testing  -  normal  or  calibration   of TGT #1 indicator. HI LO switch Used to select high and low calibration points of TGT #1 system indicator when NOR CAL switch is placed to CAL. Variable control Used  to  check  full  range  of  operation  of  TGT  #1  system  indicator  when NOR CAL switch is placed to NOR. TURBINE GAS TEMP NO. 2 NOR CAL switch Used  to  select  mode  of  operation  for  testing  -  normal  or  Calibration  of TGT #2 indicator. HI LO switch Permits  selection  of  high  and  low  Calibration  points  of  TGT  #2  system indicator when NOR CAL switch is placed to CAL. Variable control Permits   checking   full   range   of   operation   of   TGT   #2   system   indicator when NOR CAL is placed to NOR. GAS GEN SPEED NO. 1 NOR CAL switch Selects mode of operation for Ng #1 indicator in normal or Calibration. HI LO switch Used  to  select  high  and  low  Calibration  points  for  Ng  #1  indicator  when NOR CAL switch is placed to CAL. Variable control Permits  checking  of  Ng  #1  indicator  over  its  range  of  operation  when NOR CAL switch is placed to CAL. 3-4

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business