Page Title: e. Loosen locking nut
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

2-8.1 TM 55-4920-400-13 e. Loosen  locking  nut  (fig.  2-2)  and  turn  adjust- ment  screw  until  associated  microswitch  is  actu- ated and solenoid valves are heard to operate at re- quired  safety  relief  point.  Turn  vacuum  bellows adjustment  screw  clockwise  to  decrease  and  coun- terclockwise  to  increase  the  vacuum  at  which  mi- croswitch is actuated. Turn pressure bellows adjust- ment   screw   counterclockwise   to   decrease   and clockwise  to  increase  the  pressure  at  which  micro- switch is actuated. f. Tighten  locking  nut  on  adjustment  screw  or screws  which  were  reset,  being  careful  not  to  dis- turb  setting  of  adjustment  screw. g. Turn off test set in accordance with procedure given in paragraph 2-27. k.  Replace bottom front panel of test set and se- cure 10 captive fasteners.