TM 5-6350-275-24&P
3-88.
REPLACE J-SIIDS STARGATE 1000 INTERFACE ASSEMBLY (Hinged). (See Figure 3-45).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Wear ESD wriststrap while working on
Tools:
equipment.
Open End Wrench, (item 7, App B)
Materials/Parts:
J-SIIDS Stargate 100 Interface Assembly (Hinged)
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Replace
(1)
Remove the slip-on terminal strip from Stargate 1000 PWA, TB-1 (7).
(2)
Using a flat tip screwdriver, remove screw (3), and lower the hinged panel assembly (5).
(3)
Tag and remove wiring, using a flat tip screwdriver from TB-A, TB-B, TB-C, TB-D, TB-E, and TB-F (6).
(4)
Using a flat tip screwdriver, remove the two screws (4) holding the J-SIIDS Stargate Interface Assembly (5)
to the J-SIIDS enclosure (14) and remove.
b. Installation
(1) Align the J-SIIDS Stargate Interface Assembly (5) up with the two J-SIIDS enclosure standoffs and secure
the Assembly with two screws (4).
(2) Using a flat tip screwdriver, connect the tagged wires to TB-A through TB-F (6).
(3) Raise the hinged panel assembly (5) and secure to J-SIIDS enclosure (14) with screw (3).
(4) Connect slip-on terminal strip to Stargate 1000 PWA TB-1 (7).
(5) Reconnect input power.
(6) Close, lock and secure the J-SIIDS enclosure door.
3-175