• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3-43. Removal and Replacement of SubRADC (Leda), With Power Supply, (Exterior) Assemblies
REPLACE LEDA FLEX PWA.

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  236    237    238    239    240  241  242    243    244    245    246  
img
. .
TM 5-6350-275-24&P
3-83.
REPLACE 12 VDC, 12 POINTS, EXTERIOR SUB-RADC (LEDA). (See Figure 3-44).
This task consists of:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Wear ESD wriststrap while working on
Tools:
equipment.
Open End Wrench, (item 14, App B)
Materials/Parts:
12 Point Exterior Sub-RADC (Leda)
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) Remove slip-on terminal strip from Leda Flex PWA TB-7 (3).
(2) Remove slip-on terminal strips (19), (18), and (17) from Leda Flex Termination PWA (1).
(3) Using an open end wrench, remove the four nuts (5) holding the Leda Panel Assembly to enclosure and
remove the Leda Panel Assembly (6).
b. Installation
(1) Align the Leda Panel Assembly (6) mounting holes up with the enclosure standoffs and secure with four
nuts (5).
(2) Connect slip-on terminal strips (19), (18) and (17) to Leda Flex Termination PWA (1).
(3) Connect slip-on terminal strip to Leda Flex PWA TB-7 (3).
(4) Reconnect input power.
(5) Replace enclosure cover and secure.
3-169


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.