TM 5-6350-275-24&P
3-73.
REPLACE TAMPER SWITCH. (See Figure 3-42).
This task covers:
a. Remove
b. Install
INITIAL SETUP
Equipment Condition:
General Safety Instructions:
Input power removed
Remove all jewelry while working on
Enclosure access cover removed
equipment.
Materials/Parts:
Wear ESD wriststrap while working on
Tamper switch
equipment.
WARNING
Shut off power source before attempting to disconnect, service, or connect wires or cables.
Failure to do so may result in serious injury or death.
a. Removal
(1) Tag and remove the two slip-on connectors (5) from Tamper Switch (6), by holding and pulling out on
connectors.
(2) Using a flat tip screwdriver, remove the two screws (8) and flat washers (7) holding Tamper Switch (6) to
enclosure.
(3) Remove Tamper Switch from enclosure.
b. Installation
(1)
Align Tamper Switch (6) up with enclosure mount (13) and secure with two screws (8) and flat washers (7).
(2)
Connect the tagged wires and connectors (5) to Tamper Switch (6).
(3)
Reconnect input power.
(4)
Replace enclosure cover and secure.