TM 5-6350-264-14&P-10
NAVELEX EE 181-AA-OMI-110/E121 C-9412
T.O. 31S9-2FSS9-1-10
Table 5-2. Troubleshooting Procedures - Continued
Trouble
Probable cause
Corrective action
}
1. (Cont)
a. (Cont)
J4-12 to TB11-C-1
J4-12 to TB11-C-2
via P1/J12-11
J4-12 to TB11-C-3
}
J5-4 to TB12-D-1.
J5-4 to TB12-D-2
via P1/J12-12
J5-4 to TB12-B-3
}
J5-12 to TB12-D-1
J5-12 to TB12-D-2
via P1/J12-13
J5-12 to TB12-D-3
}
J6-4 to TB12-E-1
J6-4 to TB12-E-2
via P1/J12-14
J6-4 to TB12-E-3
}
J6-12 to TB12-E-1
J6-12 to TB12-E-2
via P1/J12-15
J6-12 to TB12-E-3
i.
If meter indicates more than 0 ohms, dis-
connect P1 from bottom of status proces-
meter leads to the following points:
P1-3 to TB8-F-1
P1-3 to TB8-F-2
P1-3 to TB8-F-3
P1-4 to TB8-F-1
P1-4 to TB8-F-2
P1-4 to TB8-F-3
P1-5 to TB9-A-1
P1-5 to TB9-A-2
P1-5 to TB9-A-3
P1-7 to TB9-A-1
P1-7 to TB9-A-2
P1-7 to TB9-A-3
P1-8 to TB10-B-1
P1-8 to TB10-B-2
P1-8 to TB10-B-3
P1-9 to TB10-B-1
P1-9 to TB10-B-2
P1-9 to TB10-B-3
P1-10 to TB11-C-1
P1-10 to TB11-C-2
P1-10 to TB11-C-3
P1-11 to TB11-C-1
P1-11 to TB11-C-2
P1-11 to TB11-C-3
5-12
5-12