3-9. Cable Assemblies Fault Isolation. If equipment malfunctions cannot be corrected by performing all other normal
fault isolation (FI) procedures, a defective cable assembly (W552, W553, W554, or W556) may be the cause. One
method for making this determination is by cable assembly substitution. The general procedure for this consists of first
disconnecting a suspected cable assembly (but leaving it in place), then obtaining a replacement cable assembly and
stringing it out in the most direct route from unit to unit. If the replacement cable corrects the problem, the defective
cable should be removed and the replacement installed in accordance with the appropriate procedure in section IV. A
second method is to test the cable assembly following the appropriate procedure in section V. An overall cabling
diagram for the MTS is shown in FO-3 (in back of manual).