a. Continuity Test. During a continuity test, the timing and control function applies a dc voltage to the CUT data
lines. Continuity test results are returned (through 72 data lines) to the probe control logic, which applies the probe data
signal to the error detect function or self-test function (during a self-test).
b. Functional Test. During a functional test, the reed switch control opens or closes the CUT reed switch under
control of the timing and control function. Test pattern data is applied to the CUT. The functional test results are
returned (through the 72 data lines) to the probe control logic. The probe control logic transfers the data to the error
detect logic for comparison with stored information. Either the GO or the NO-GO indicator is turned off by the timing and
control function according to the test results.
2-14. Power Function. Power to operate the MTS is provided by an external 135v power supply. The 135v input is
converted to 5v, 15v, +12v, +5v reserve, and +5v logic voltages by dc/dc converters PS1 and PS2. Power is
distributed within the MTS as shown in figure 2-9.
2-22
|