TM 11-6625-646-15
SECTION VII
DEPOT OVERHAUL STANDARDS
repaired electronic equipment in TM SIG 355-1, TB SIG
7-1. Applicability of Depot Overhaul Standards
355-2, and TB SIG 355-3 form a part of the
Test set TS-1894/ASM must be tested thoroughly after
requirements for testing this equipment.
rebuild or repair to insure it meets adequate
performance standards for return to stock or reissue.
b. Technical Publications. No other publication is
Use the tests in this section to measure the performance
applicable to this equipment.
of the repaired test set. It is mandatory that repaired
c. Modification Work Orders.
Perform all
equipment to be reissued, or returned to stock for
modification work orders applicable to the TS-1894/ASM
reissue, meet all performance standards outlines in this
before making the tests specified. DA Pam 310-7 lists
section.
all applicable MWO's.
7-2. Applicable References
7-3. Test Facilities Required
a. Repair Standards. Applicable procedures of the
The following items are required for depot testing:
depot performing this test and the general standards for
Item
NATIONAL stock No. or part No.
Technical manual
Ac power supply ................................ ................................
W5MT3A or equiv
Dc power supply ................................ ................................
HWP712B or equiv
Decade resistance................................ .............................
AN/URM-2 or equiv
Variable resistor 1,000 ohms ................................ .............
T10A1000 or equiv
Electronic voltmeter ME-30 (*)/U (vtvm)............................
6625-00-643-1670 ......................
TM 11-6625-320-12
Manometer................................ ................................ ........
34BFZ-20 (Meriam)
Multimeter TS-352B/U................................ .......................
6625-00-553-0142 ......................
TM 11-6625-366-15
Dc voltmeter, 0 to 15 volts ................................ ................
341 or equiv
7-4. Preliminary Procedures
c. Connect power cable A02VS309-2 between
receptacle J61 115V 60 ~ and a 115-volt 60cycle power
a. Remove the front panel attaching screws.
source.
Remove the panel-chassis from the case.
d. Connect power cable A02VS309-3 between
b. Check that the controls are positioned as
receptacle J62 115V 400 ~ and a 115volt 400-cycle
follows:
power source.
Control
Function
FUNCTION switch...........................
AC PWR
7-5. Ac Power Supply Circuit and Meter
ASE MODE switch ..........................
OFF
Rectifier Circuit Test
115V 400 ~ POWER switch ............
Off (down)
a. Connect the vtvm between DEM/MOD CARD
PUMP switch................................ ...
Off (down)
Adapter switch................................ .
POS-B
TESTER receptacle pins 12 (gnd) and 18. Adjust the
AXES METERS READ switch .........
OPEN LOOP
vtvm to indicate ac volts.
PEDAL POT control ........................
Centered
b. Set the 115V 400- POWER switch to on
CHANGE 4 65
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |