TM 11-6625-3056-12
2-7.
PATRIOT VOICE LINK END-TO-END TSTING
General
Use: Tests one-half of a path (to or from) at a time.
Advantages: Fault can be isolated to one-half of a path or the other (to or from).
Disadvantages: (1) Multiplexers/demultiplexers cannot be end-to-end tested because their
input/output date rates are different. (2) For some system on nonlocal testing, the path may be so
long that two TS-3981s would be required. Both of these disadvantages can be overcome by
loopback testing (para 2-8).
Procedure
Select input and output points of path under test.
On one end, connect DATA OUT from TS-3981 to data input of path under test. Use Interface
Box if necessary.
On other end, connect data output from path under test to DATA IN of TS-3981.
Use
Interface Box if necessary.
Set TS-3981 controls as follows:
POWER
ON
PATTERN
LONG
OPERATION
4W
CORRELATOR LOOP
OPEN
DATA ON/OFF
ON
RATE SELECT
As required for path under test
DISPLAY SELECT
ERRORS
ACTIVITY indicator will be lit.
Press SINGLE ERROR several times:
Display will advance one count each time SINGLE ERROR is pressed which indicates setup
is proper.