TM 11-6625-3056-12
2-5.
SELF-TEST (cont)
6
Sync Time
Set controls as follows:
PATTERN
Keep at LONG
OPERATION
2W-R
CORRELATOR LOOP
OPEN
DATA ON/OFF
OFF
RATE SELECT
Keep at 7 (32 kb/s)
DISPLAY SELECT .... SYNC TIME MSEC
Keep DATA OUT connected to DATA IN.
Press RESET:
Display must read 0.
Set DATA ON/OFF to ON:
Display must rapidly advance count (1000 counts per second).
Set OPERATION to 4W:
Display must stop advancing count and must display some number (representing the
length of time, in milliseconds, from the time DATA ON/OFF control was set to ON
and the time OPERATION control was set to 4W).
Press RESET:
Display must read 0.
7.
Two-Wire
Set controls as follows:
Operation
PATTERN
Keep at LONG
OPERATION
Keep at 4W
CORRELATOR LOOP
Keep at OPEN
DATA ON/OFF
Keep at ON
RATE SELECT
Keep at 7 (32 kb/s)
DISPLAY SELECT
Keep at SYNC TIME MSEC
Keep DATA OUT connected to DATA IN.
Set OPERATION to 2W-T:
ACTIVITY indicator must extinguish.
Set OPERATION to 2W-R:
END
ACTIVITY indicator must remain unlit.
2-9
|