1-7.
EQUIPMENT DATA
The Test Set Error Detector TS-3981/P tests digital transmission paths and is specially designed to test the Data
Buffer TD-1065/G. It includes a transmitter that produces a diphase output and a receiver that accepts a diphase
input, detects and counts errors, and measures synchronization time.
Physical
19 in. wide x 5.25 in. high x 14 in. deep overall; 11.5 lb.
Power
105 to 125 volts, 48 to 420 Hz, single-phase, 00 watts maximum. Five-foot, 3-wire power cable
permanently attached to rear panel. Spare fuse supplied.
Measurements Errors and synchronization time.
Data Rate
0.6, 1.2, 2.4, 4.8, 9.6, 16, 32, 32 and 38.4k bits per second; set by front-panel control.
Pattern
Long with length of 215-1 (32,727) bits or short with length of 15 bits; set by front-panel control.
Error
Front-panel pushbutton injects a single error in output pattern each time it is pressed.
Injection
Data Output
Unframed, nonconditioned diphase; 4.5 to 5.5 volts peak-to- peak into 600 ohms, balanced.
Available at two front-panel binding posts.
Data Input
Unframed, nonconditioned diphase; 5 volts peak-to-peak nominal, down to 5 volts peak-to-peak
attenuated by over 3 miles of WF-16 field wire; balanced, 600 ohms input impedance. Applied to
two front-panel binding posts. Green front-panel indicator lamp lights when data is being received.
Input/Output
Front-panel control sets input/output for 4-wire operation output connectors wired to output
Switching
(circuits and input connectors wired to input circuits), 2-wire transmit (output connectors wired to
output circuits and input connectors open), and 2-wire receive (output connectors wired to input
circuits and input connectors open).
Sync
Front-panel control allows receiver to be operated in one of two modes. Open: received data is
loaded continuously into the register and simultaneously compared to the output of the register to
detect differences (errors). Closed: the register is first synchronized to the received data, then
allowed to run independently and compared to the received data to detect differences (errors).