TM 11-6625-3024-14/EE641-AC-MMA-010/E154 SYSEX/TO 33AA50-5-1-1
connector P13/J13 on the Connector Panel
+28 Vdc from connector P4 on the connector
Assembly to connector J3 on the Connector Panel
panel is applied through fuses F1 and F2. Fuse F1
Assembly. Connector J3 provides +28 Vdc power
is a 5 amp SLO-BLO fuse and provides for +28
to the transport.
Vdc short circuit protection in the transport. +28
Vdc from fuse F1 is routed through connector
Fuse F2 on the Connector Panel is a 3 amp
J13/P13 on the Power Switch Assembly to the N.C.
SLO-BLO fuse and provides for +28 Vdc short
contacts on the SYSTEM-ON/OFF switch. Power
from the SYSTEM-ON/OFF switch is routed
circuit protection to all circuit card indicator lamps.
+28 Vdc from fuse F2 is routed through connector
through the N.C. contacts on the transport power
J12/P12 to the mother board circuit card assembly
switch to a CURRENT LOOP jack. The +28 Vdc is
routed from the CURRENT LOOP jacks through
for distribution to all circuit card indicator lamps.
4-16
|