TM 11-6625-3024-14/EE641-AC-MMA-010/E154 SYSEX/TO 33AA50-5-1-1
Table 3-1. Front Panel Controls and Indicators
Control/Indicator
Function
STATUS INDICATION
Note
A test jack over each status indicator is
provided to monitor each status line at
the Exerciser input.
Indicates when the transport tape has reached
EOT
END-OF-TAPE.
Indicates when the transport tape has been
BOT
positioned at the BEGINNING-OF-TAPE.
Indicates when the transport is in rewind mode.
IN REWIND
Indicates when the transport is ready to read or
READY
write data and all transport interlocks are closed.
Indicates when the transport and the Exerciser are
SELECTED
set to the same select number (1 through 4).
Indicates when the transport tape cartridge is write
WRITE ENABLE
enabled.
DATA CONTROL
Note
All Data Controls except WRITE RESET
are push-ON and push-OFF pushbutton
switches. When the switch indicator is lit,
the function is enabled (ON).
Places the transport in continuous read mode
CONT. READ
when lit. When not used the read circuits are
delayed 14 milliseconds after RUN FORWARD or
RUN REVERSE is initiated.
Commands the Exerciser to repeat the recorded
REPEAT ON ERROR
block in which an error has been detected. Three
attempts are made to recover the detected error
before a HARD ERROR is counted, and the
original operation is resumed. Used only with the
BLOCK MODE and 4K BLOCK mode switches.
3-3
|