TM 11-6625-3023-14/ET904-AA/MMA-010/E154 TS3684/TO 33A1-12-1173-1
Table 6-1. Test Set Troubleshooting - Continued
Fault indication
Probable cause
Corrective action
10 -
cont
b.
Switch S4 in
EXTERNAL
position.
(1)
Switch S5
in OPEN
position.
+140 VDC
8% not
present.
(2)
Switch S5
in SHORT
position.
+78 VDC
10% not
present.
c.
Switch S4 in
COAX
position.
(1)
Switch S5
in OPEN
position.
+140 VDC
8% not
present.
(2)
Switch S5
in SHORT
position.
+78 VDC
10% not
present.
11. No voltage
between test
points F and
A. Switches S2
and S3 pressed
at the same time.
6-5
|