2-31. IMPEDANCE MATCHING NETWORK A7 REPLACEMENT.
MATERIALS/PARTS: Signal combiner assembly A7 (P/N 629-0700-001)
PRELIMINARY PROCEDURE: Remove A6 and A8 assembly (para 2-19).
REMOVAL
1. Disconnect wire connector (1).
2. Using screwdriver, remove two screws (2) and A7 assembly (3).
INSTALLATION
1. Position A7 assembly (3) on bracket (4).
2. Install two screws (2).
3. Using screwdriver, tighten two screws (2).
4. Connect wire connector (1).
FOLLOW-ON MAINTENANCE Install A6 and A8 assembly (para 2-19).
2-77