2-4. OPERATING PROCEDURES. (CONT)
AUDIO TONE SELECTION
EL9LX046
Enter a Iocalizer rf carrier frequency into test set (FREQUENCY/MODE SELEC-
TION, steps 1 through 6, page 2-16).
NOTE
The next step adds 1020 Hz audio identification tone to Iocalizer signal. (The audio tone
cannot be added to glide slope signal.)
2. Press and hold 1020 Hz key until it lights.
NOTE
The next step removes 1020 Hz audio tone.
3. Press and hold 1020 Hz key until its lamp goes off.
NOTE
The next step removes 90 Hz audio modulation signal for a flag check (Iocalizer or glide
slope modes).
Press and hold 90 Hz key until its lamp goes off.
4.
NOTE
The next step returns 90 Hz audio modulation signal.
5. Press and hold 90 Hz key until it lights.