TM 11-6625-2937-13
(2) Set equipment controls as follows:
(6) Remove program card from digital tester card
reader slot and insert A6 program card No. 2 in slot.
Control
Setting
(7) Set digital tester TEST RATE PER SEC switch
Control-interface unit:
to 2M and NUMBER OF TESTS switch to 4M.
MODE SELECT
MODULE TEST STE
(8) Repeat steps (4) and (5).
POWER ON/OFF
ON
(9) Set digital tester DISPLAY switch to PROBE.
Digital tester:
(10)Monitor the following A6 integrated circuit pins (fig.
POWER
On (up)
UUT POWER
On (up)
TEST switch and verify that at the termination of the test
TEST RATE PER SEC
200K
the proper count is displayed on digital tester display.
NUMBER OF TESTS
2M
Test point
Count
DISPLAY
PASS/FAIL
PROBE THRESHOLD
2V
U22-1
3154
U22-13
4162
(3) Insert A6 program card No. I in digital tester
U7-1
3
card reader slot.
U7-2
11
(4) Press digital tester PROGRAM ENTER switch
U7-3
6
down. Observe that red ERROR indicator goes out and
(11) Remove program card, turn off equipment
white READY indicator lights.
power, and disconnect test setup.
(5) Press digital tester TEST switch. Verify that red
TEST indicator lights during test. Repeat test and verify
that green PASS indicator lights at end of second test.
5-20
|