TM 11-6625-2884-30/NAVAlR 16-35TS3615-2
3.
Use a jumper wire to
connect the following
WI connector pins to
cabinet ground. The
correct status
indicator illuminates
as its pin is grounded.
CONNECTOR PIN INDICATOR
LIGHT
W1-P2
1
CHANNEL
1 SORTER LOAD COMMAND
2
CHANNEL
1 SORTER LOADED
3
CHANNEL
2 SORTER LOAD COMMAND
4
CHANNEL
2 SORTER LOADED
5
CHANNEL
1 SLO LOAD COMMAND
6
CHANNEL
1 SLO LOADED
7
CHANNEL
2 SLO LOAD COMMAND
8
CHANNEL
2 SLO LOADED
9
CHANNEL
1 A
1 B
10
CHANNEL
11
CHANNEL
2 A
12
CHANNEL
2 B
13
CHANNEL
1 CON SCAN
14
CHANNEL
1 TC RANGE JAM
15
CHANNEL
2 CON SCAN
16
CHANNEL
2 TC RANGE JAM
17
CHANNEL
1 SLO ACCUR
18
CHANNEL
1 SPARE
19
CHANNEL
2 SLO ACCUR
20
CHANNEL
2 SPARE
a.
If any of the sta-
tus signal lamps
fails to light,
check Cable W1.
If W1 is good,
replace 1A2.
END OF TEST.