TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
RF OUTPUT LEVEL CHECK (Continued)
Disconnect power from RF
modulation assembly.
Place assembly right
side up and substitute
circuit cards A1 and A2.
Connect power to drawer.
Output power level shall
be +3 dBm min. If power
level is normal go to
step 3.
Repeat steps 1 and 2 for
FREQ SEL set for F2 and
F3.
Set power meter to mini-
mum sensitivity before
changing inputs. Exces-
sive power input will
damage meter.
3-16
|