TM 1-6625-736-13&P (4) Turn on external power source. (5) Turn DAU power switch ON. (6) Set signal generator to produce an approximate square wave at 50 KHz and 5V amplitude. (7) Select range on the DVM to most accurately display 5Vdc. (8) Connect 50KHz output of signal generator to EXT CLK input of the Electronic Test Set. (9) Connect shield of EXT ACC input on the Electronic Test Set to signal generator signal ground. (10) Connect negative (-) lead of DVM to ANALOG GROUND on DAU Acquisition board, or pin  C  of  ACC  1 input on DAU front panel. (11) Connect positive ( + ) lead of DVM to pin C of ACC 1 output on the Electronic Test Set. d. SIGNAL OUTPUT LEVEL NOTE The absolute value of the output signals is not critical (within a few tenths of a volt) but the difference  between  them  is  important.    Therefore  record  the  high  and  low  voltages  seen  on the DVM. At   this   point   with   the   gain   select   on   1:1,   the   output   of   the   DVM   should   stabilize   on   about   5.000   V   for approximately  6  seconds,  then  stabilize  on  approximately  4.000  V  for  6  seconds.    If  the  meter  does  not  have sufficient time to stabilize, reduce the input frequency on the EXT CLK input. (1) Select 1:4 gain range on the Electronic Test Set.  Record high and low DVM readings. (2) Select 1:16 gain range on the Electronic Test Set.  Record high and low DVM readings. (3) Select 1:64 gain range on the Electronic Test Set.  Record high and low DVM readings. (4) Repeat steps 1 to 3 for accelerometer channels 2, 3 and 4.  Do this by measuring the output voltage at the appropriate rear panel connector. (5) Select 54 mV/g on the Electronic Test Set. (a) Connect negative (-) lead of DVM to ANALOG GROUND on DAU Acquisition board, or pin B of ACC 1 input on DAU front panel. (b) Connect positive ( + ) lead of DVM to pin B of ACC 1 output on the Electronic Test Set. (c) Select 1:4 gain range on the Electronic Test Set.  Record high and low DVM readings. (d) Select 1:16 gain range on the Electronic Test Set.  Record high and low DVM readings. (e) Select 1:64 gain range on the Electronic Test Set.  Record high and low DVM readings. 4-4

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business