TM 1-6625-735-14
TABLE NO. 3-25. INDICATORS NO. 1 SLEW UP And NO. 1 HOT SLEW Do Not Go On When
MANUAL SLEW 1 Switch Is Pressed And Held At UP.
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Test lamps for condition before continuing.
During the following steps, note the status
(on or off) of all lamps.
1. Press and hold MANUAL SLEW 1 control at UP. INDICATORS NO. 1 SLEW UP
and NO. 1 HOT SLEW shall light.
Step 1. If indicator lamps do not go on, go to 2.
Step 2. If indicator lamps go on, go to 3.
2. Check switch S10 for continuity.
Step 1. If continuity exists, replace component board assembly A3.
Step 2. If continuity does not exist, replace switch S10.
3. Release MANUAL SLEW 1 control. INDICATORS NO. 1 SLEW UP and NO. 1
HOT SLEW shall go off. Go to 4.
4. If indicator lamps do not go off, replace switch S10.
TABLE NO. 3-26.
INDICATORS NO. 1 SLEW DN And NO. 1 HOT SLEW Do Not Go On When
MANUAL SLEW 1 Switch Is Pressed And Held At DN.
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Test lamps for condition before continuing.
During the following steps, note the status
(on or off) of all lamps.
1. Press and hold MANUAL SLEW 1 control at DN. INDICATORS NO. 1 SLEW DN
and NO. 1 HOT SLEW shall light.
Step 1. If indicator lamps do not go on, go to 2.
3-24
|