TM 1-6625-735-14
TABLE NO. 3-6.
Test Set Circuit Breaker Is Pushed In. (Cont)
TEST OR INSPECTION
CORRECTIVE ACTION
14. Connect multimeter + lead to - terminal of PS1 and - lead to T/C terminal of PS1.
Step 1. If multimeter indicates -15 6 0.15 vdc, trouble is elsewhere. Go to 15.
Step 2. If multimeter does not indicate -15 6 0.15 vdc, replace PS1.
15. Pull out POWER 115 VAC 400 Hz TEST SET circuit breaker.
TABLE NO. 3-7. All STABILATOR And SAS SYSTEM Indicators Do Not Go On When LAMP
TEST Switch Is Pressed And Held And Indicators Do Not Go Off When LAMP TEST Switch Is
Released.
TEST OR INSPECTION
CORRECTIVE ACTION
1. Press and hold LAMP TEST control and check that all STABILATOR INDICA-
TORS and SAS indicators go on.
Step
1.
If
all indicator lamps are on, go to 5.
Step
2.
If
all indicator lamps are off, go to 3.
Step
3.
If
all STABILATOR INDICATOR lamps are off, go to 2.
Step
4.
If
all SAS indicator lamps are off, go to 3.
Step
5.
If
one or more indicator lamps are off, go to 4.
2. Check filter FL4 for continuity.
Step 1. If continuity exists, go to 3.
Step 2. If continuity does not exist, replace filter FL4.
3. Check switch S24 for continuity.
Step 1. If continuity exists, replace component on board assembly A3.
Step 2. If continuity does not exist, replace switch S24.
4. Check for malfunctioning lamps.
Step 1. If any lamps are malfunctioning, replace lamps.
Step 2. If all lamps are good, replace component on board assembly A3.
3-12
|