TM 1-4920-458-13&P
4-35.
REMOVE AND REPLACE CAPACITOR (Cont)
(Sheet 2 of 2)
4-35.1. REMOVAL
a.
Remove front screw (1) and nut (2) from front of capacitor clamp (3).
b.
Rotate capacitor clamp (3) to access capacitor clamp screw (4).
c.
Loosen capacitor clamp screw (4) from capacitor clamp (3) and remove capacitor (5) from clamp (3).
d.
Tag and remove five wire connectors (6) from capacitor (5) by removing two screws (7). Install screws (7) back
into capacitor (5).
e.
Remove capacitor (5).
4-35.2. INSTALLATION
a.
Remove two screws (7) from new capacitor (5), and connect five wire connectors (6) to capacitor (5).
b.
Install capacitor (5) into capacitor clamp (3) and tighten clamp screw (4) to hold capacitor (5).
c.
Remove tags from five wire connectors (6).
d.
Rotate clamp (3) and aline.
e.
Install screw (1) with nut (2).
4-35.3. FOLLOW ON MAINTENANCE
Performance check (para. 2-5)
END OF TASK
4-47
|