TM 1-4920-458-13&P
4-33.
REMOVE AND REPLACE MOTOR/PUMP (Cont)
(Sheet 2 of 2)
4-33.1. REMOVAL
a.
Disconnect rigid pressure lines (1,2, & 3) from motor/pump (4).
b.
Disconnect connector (5) from motor receptacle (6) by turning counter-clockwise.
c.
Tip chassis (7) forward and remove four screws (8) from bottom chassis (7).
d.
Remove motor/pump (4).
e.
Remove fittings (9, 10 and 11)) from motor/pump (4).
4-33.2. INSTALLATION
a.
Apply Sealube (D6) on all threads of fittings (9, 10 and 11).
b.
Install fittings (9, 10 and 11) on motor/pump (4).
c.
Position motor/pump (4) over mounting holes in chassis (7) and secure with four screws (8) through bottom of
chassis (7).
d.
Connect the connector (5) to the motor receptacle (6) by rotating clockwise until connector (5) is hand tight.
e.
Reconnect rigid pressure lines (1,2, & 3) to their respective ports.
4-33.3. FOLLOW ON MAINTENANCE
Performance check (para. 2-5)
END OF TASK
4-43
|