TM 1-4920-458-13&P
4-17. REMOVE AND REPLACE RATE OF CLIMB INDICATOR (Cont) (Sheet 2 of 2)
4-17.1.
REMOVAL
a.
Disconnect hose (1) and remove fitting (2) with preformed packing (3) from end of indicator (4).
b.
Remove three nuts (5) from underside of control panel (6).
c.
Remove three screws (7) securing indicator (4) to control panel (6).
d.
Remove indicator (4) from tester control panel (6).
4-17.2.
INSTALLATION
a.
Install indicator (4) in control panel (6) and align mounting holes.
b.
Secure indicator (4) to control panel (6) with three screws (7) from outside control panel (6) and install three nuts
(5).
c.
Install fitting (2) and connect hose (1) with preformed packing (3) to port at end of indicator (4).
4-17.3.
FOLLOW ON MAINTENANCE
Calibration (TB 43-180)
Performance check (para. 2-5)
END OF TASK
4-11
|