3-1. PREPARATION FOR USE. Prepare the tester for
use as follows:
k. Connect external oxygen supply to one inlet of
tester inlet fitting and securely cap the other inlet to
withstand pressure of 450 psi.
a. Carefully remove the tester from shipping
container(s) as required and remove any extraneous
l. Set A-14 regulator to NORMAL and open
cushioning material used to protect the control panel
oxygen supply shutoff valve; allow oxygen pressure to
during shipment.
build up to 450 psi.
b. Inspect the case assembly for evidence of
m. Connect power cable to 115 volt, 60 Hz power
damage or breakage and make sure the cover closes
source. Tester is now ready for operation.
and latches securely.
c. Check instruments and controls to assure all
3-2.  PREPARATION FOR SHIPMENT.  (See figure
attaching parts are tight.
1-1.) Prepare tester for shipment as follows:
d. Operate controls and switches to determine
a. Accomplish steps b thru h of paragraph 3-1 to
positive action.
assure that tester is in good condition at time of
e. Inspect cables and jacks for evidence of
shipment.
damage.
b. Wrap oxygen hose assembly (13) and cables (1,
f. Inspect oxygen hose assembly for kinks,
3, 4, 14) with suitable material to prevent damage to
abrasion or other damage.
inside of cover or to panel surface during shipment and
stow cables and hose between cover and panel. Latch
g. Check condition of fuse and name and data
cover securely.
plates.
c. Pack tester in accordance with packing method
WARNING
4Q.
Do not use oil or grease on
(1) Enclose tester in weather resistant box of
oxygen equipment.  Oil, even in
paperboard per PPP-B-636, Type CF, with suitable
minute quantities, coming In con
dunnage such as microfoam per MIL-P-11 6 if loose fit.
tact with oxygen, may cause an
Include dessicant per MIL-D-3464, Type 1, 2 or 3, and
explosion. Dust, lint or fine metal
indicator card. Seal box with shipping tape.
particles (also filing) are also
(2) Enclose box within aluminized vapor
dangerous.
barrier bag per MIL-P-131B, evacuate air from bag and
heat seal bag.
h. Inspect tester for cleanliness; tester must be
free of oil and dirt.
(3) Enclose package In a second weather
resisbox and seal box with non-asphaltic reinforced
i. Following satisfactory visual inspection, prepare
shipping tape.
tester for operation In accordance with subsequent
steps.