(13) If an AFCS panel is to be tested, connect as follows: (See fig. 2-5.)
(a) Connect cable plug P1 of W4 to test set receptacle panel J1. Connect cable plug P2 to AFCS
panel receptacle J1.
(b) Connect cable plug P1 of W5 to test set receptacle panel J2. Connect cable plug P2 to AFCS
panel receptacle J2.
(14) If a longitudinal or a collective CCDA actuator is to be tested, connect plug P1 of cable W6
to test set receptacle CCDA J6. Connect cable plug P2 to the receptacle on the CCDA. (See fig. 2-6. )
(15) Refer to TM 55-1520-240-23 for instructions for testing the AFCS computer, AFCS panel,
and CCDA actuators of the CH-47D Advanced Flight Control System (AFCS).
NOTE
If HOLD light comes on, when not called for in test, cycle MODE
switch to ON, then OFF, to turn out light.
Table 2-3. Self Test
METER/lNDICATOR
POSITION
SWITCH OR CONTROL
NORMAL RESULT
SERVO SIMULATION Group
RESET
ILCA SIMULATION PITCH
RESET
ILCA SIMULATION ROLL
RESET
ILCA SIMULATION YAW
NORM
ACTUATOR SIMULATION CCDA
TF2
ACTUATOR SIMULATION DASH
NORM
LCT
CONTROL PANEL SIMULATION
Group
SELECT
AFCS
00-0-B-0
CIRCUIT SELECT
AC
METER
200V
RANGE
OFF
AFCS PO WER
115VAC/400-Hz
OFF
AFCS POWER
+28VDC
OFF
LCT POWER
+28VDC
6 VAC MAX
00-1
SELF TEST CIRCUIT SELECT
112.2 to 117.7 VAC
ON
AFCS POWER 115V/400-Hz
then
OFF
DC
METER
-0.6 to +0.6 VDC
00-2
SELF TEST CIRCUIT SELECT