Table 3-2. Operational Check-Continued
Step
Position of shutter test set switches
Required indication
19
MASTER switch: INTERNAL TESTS + 28VDC,
OPER lamp lights
POWER switch ON
20
OPER lamp goes out
21
MASTER switch INTERNAL TESTS + 19VDC,
RECY lamp lights
POWER switch ON.
22
RECY lamp goes out
23
MASTER switch INTERNAL TEST + 28VDC,
DATA lamp lights
POWER switch ON
24
DATA lamp goes out
25
MASTER switch INTERNAL TEST + 28VDC;
ELECT FLASH lamp lights
POWER switch: ON
26
ELECT FLASH lamp goes out
90 and AUTO lamps light
27
MASTER switch- CONTROL PANEL, POWER
switch ON
90 and AUTO lamps go out
28
29
MASTER switch RELAY TEST, RELAY ASSY
D lamp lights
switch position 2, POWER switch ON
30
Set all test panel switches to OFF or extreme
D lamp goes out.
counter- clockwise position
b. Troubleshooting Table. Steps referenced in the
malfunction column refer to the operational check
3-6. Direct Support Troubleshooting Procedures
a.
Direct support troubleshooting procedures
(table 3-3) supplements the equipment performance
NOTE
checklist In TM 11-6760-238-12. If the symptoms are
not known, perform the preoperational test (TM 11-6760-
238-12) and observe any malfunction. Table 3-3 lists the
Perform the operation given in TM  11-6760-238-12
malfunctions, test or inspection, and corrective action.
before using this chart unless the trouble has already
Refer to figure* FO-4 for location of parts.
been localized
Table 3-3. Direct Support Troubleshooting
SYMPTOM
PROBABLE TROUBLE
CORRECTIVE ACTION
1. DC POWER LAMPS DS1, DS2 DO NOT LIGHT (step 1)
a. Defective DC POWER lamps DS1 and/or DS2, or indicator lamp assembly A3
Replace lamps or modicator lamp assembly (para 3-8t)
b. Defective 10 ampere DC fuse Fl, or fuseholder
Replace fuse or fuseholder (para 3-8p)
c. Defective POWER switch S1
Replace POWER switch (para 3-8h)
2. AC POWER LAMPS DS3, DS4 DO NOT LIGHT (step 1)
a. Defective AC POWER lamps DS3 and/or DS4 or indicator lamp assembly A3
Replace lamps or indicator lamp assembly A3 (para 3-8t).