3-5. Daily Preventive Maintenance Checks and Services Chart
Sequence
References
Procedure
Item
No.
POWER OFF INSPECTION
See that the equipment is complete.
1
Check for looseness of exterior items, such as con-
Exterior items
2
nectors, switches, and latches. Tighten all loose
mounting screws and nuts
Check to see that mechanical action of switches and
Knobs and switches
3
knobs is smooth, and free of binding and scraping.
During operation, be alert for unusual or faulty
4
Operation
operation.
POWER ON INSPECTION
a. Connect the power cable between the POWER
Preliminary
5
connector and the power source.
b. Set the FUNCTION switch to SELF TEST.
c. Set the 28 VDC-115 VAC-OFF power switch to
28 VDC or 115 VAC as applicable.
d. Allow two minutes warm-up time.
Press the ACCEPT indicator to see that the indica-
ACCEPT indicator
6
tor lights.
Press the REJECT indicator to see that the indica-
REJECT indicator
7
tor lights.
Set the MODE switch to TEST and press the PUSH
MODE switch and
8
TO TEST switch to see that the ACCEPT indica-
PUSH TO TEST switch
tor lights
3-6. Monthly Maintenance Checks and Services Chart
Sequence
References
Procedure
Item
No.
Check cables for breaks, cuts, kinks, fraying, and
Cables
1
broken connectors; replace defective cables.
Inspect connectors for snug fit and good contacts.
Connectors
2
Check handles, latches, and hinges for looseness and
Handles, latches,
3
defects.
and hinges
Check all exposed metal surfaces for rust and cor-
Metal surfaces
4
rosion. Clean and touch up paint as required.
3-7. Quarterly Preventive Maintenance Checks and Services Chart
Sequence
References
Procedure
Item
No.
Check to see that all pertinent publications are ser- DA Pam 310-4 (Army),
Publications
1
NAVSUP-2002
viceable and current.
(Navy), TO 0-1-12
(Air Force).
Check to determine if new applicable MWO'S have TM 33-750 and DA
Modification work orders
2
Pam 310-7 (Army),
been published. ALL URGENT MWO'S must be
NAVSUP-2002
applied immediately.
(Navy),
TO 0-1-12 (Air
Force).
b. Remove dirt from the connectors with a
3-8. Cleaning
soft-bristled cloth or brush.
Inspect the exterior of the test set. The exterior
WARNING
surfaces, including the front panel and antenna,
should be clean and free of dust, dirt, grease, and
The fumes of trichloroethane are toxic.
fungus.
Provide thorough ventilation whenever
used. DO NOT use near an open flame.
a. Remove dust and loose dirt with a clean,
Trichloroethane is not flammable, but
soft cloth.
3-2