CHAPTER 2
INSTALLATION AND OPERATING INSTRUCTIONS
Section I. SERVICE UPON RECEIPT OF EQUIPMENT
2-1. Unpacking
b. See that the equipment is complete as listed
on the packing slip. If a packing slip is not avail-
a. Packaging Data. When packed for ship-
able, check the equipment against the list of
ment, the test set is placed in a corrugated car-
components in paragraph 17. Report all dis-
ton. A typical shipping carton and its contents
crepancies in accordance with paragraph 3-lc.
are shown in figure 21. The corrugated carton
Shortage of a minor assembly or part that does
is 13 1/2 inches high, 22 1/2 inches deep, and 24
not affect proper functioning of the equipment
inches wide; the volume is 6.7 cubic feet. The
should not prevent use of the equipment.
gross weight of the carton and its contents is
approximately 55 pounds.
c. If the equipment has been used or recondi-
tioned, see whether it has been changed by a
b. Removing Contents
modification work order (MWO). If the equip-
(1) Place the outer container in a location
ment has been modified, the MWO number will
that provides vertical clearance of at least twice
appear on the front panel near the nomenclature
the container height. Keep the container in an
plate. If modified, see that any operational instruc-
upright position, and open the top of the con-
tion changes resulting from the modification have
tainer.
been entered in the equipment manual.
(2) Remove the contents from the outer con-
NOTE
tainer, and then remove the inner container from
the screen foil bag. Open the inner container.
Current MWO'S applicable to the equip-
(3) Remove the top layer cushioning and all
ment are listed in DA Pam 3107.
side layers of cushioning from the inner con-
tainer.
2-3. installation of Fuses
(4) Lift the test set from the inner con-
tainer and remove the paper wrapping.
The test set is shipped with fuses installed. Be
2-2. Checking Unpacked Equipment
sure the proper fuses are inserted in the fuse
holders on the front panel of the test set. The
a. Inspect the equipment for damage incurred
following chart shows the location and ratings
during shipment. If the equipment has been dam-
of the fuses:
aged, refer to paragraph l-3b for instructions.
Fuses
Reference Symbol
Amps
Volts
Circuit
A1F1 and A1F3
1
115
Ac input
A1F2 and A1F4
2
28
Dc input
2-1